RadiSys ATCA-4616 Dokumentacja Strona 114

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 113
6
Troubleshooting
114
Responding to an IPMB isolated alarm
Themodule’sIPMChasdetectedaproblemononeorbothofitsIPMBinterfaces,andhas
isolatedtheIPMCfromtheexternalbus.
1. Verifythemoduleisseatedproperly.
2. Usethehotswapproceduretoextractandreinsertthemodule.
Iftheconditionpersists,contactRadisysTechnicalSupportforassistance.
Responding to a fruinfo fail alarm
Thefruinfostartupscriptfailedtoretrievetheinformationitneeded.
1. CheckfortheShelfFRUInvalidalarm,whichindicatesthattheShelfManag ercannotread
theShelfFRUda ta,orthattheda taisnotvalid.Ifthealarmispresent,seeShelfManager
modulebootsupindebugmodeonpage 126.
2. VerifytheshelfaddressisintheRadisysformat,asspecifiedinRadisysshelfaddress
formatonpage 65.
3. VerifytheshelfIPaddressisavalidaddre ss.
Iftheconditionpersists,contactRadisysTechnicalSupportforassistance.
Responding to a PEM absent alarm
TheRadisy sshelvesaredesignedtooperatewithtworedundantpowerentrymodules
(PEMs),butcanoperatewithonlyonePEMinstalled.However,becausesomeFRUs
specificallymonitorvoltagesfromeachPEMindividually,thoseFRUsgeneratealarmswithout
bothPEMsinstalled.Evenifthesealarmsareacknowledgedtosilencetheaudiblealarm,they
maybereassertedatanytimebecausethepowerlineisfloating.
IftheshelfistoberunwithonlyonePEMforanylengthoftime,itmaybedesirabletodisable
eventgenerationfromthevoltagesensorsonthoseFRUsforthePEMthatisremoved.This
maybedoneusingtheHPIfunctionsaHpiEventEnableSet().
Todisableeventgenerationusinghpiapp:
1. AccesshpiappfromtheLinuxshellandlistallalarms:
hpiapp
d
0
2. NotetheresourceIDoftheFRUandthesensorIDlistedinthealarmdescription.
3. Displaythesensorinformation:
q
s
b
4. VerifythatthesensorisrelatedtothepresenceofaPEM.
Przeglądanie stron 113
1 2 ... 109 110 111 112 113 114 115 116 117 118 119 ... 145 146

Komentarze do niniejszej Instrukcji

Brak uwag